Specifications |
 |
|
| |

Input |
 |
Input Voltage Range |
 |
15.5-40 VDC
|
| |
Input Transient |
|
10-50 V for 10 s,
600 V for 10 µs 50 Ω source
resistance per MIL-STD-704A,
100 V for 50 ms 0.5
Ω source resistance per
MIL-STD-1275A, ±250 V for 100
µs as per MIL-STD-1275A |
| |
Output |
 |
Output Voltage |
 |
Clamped <50 VDC
|
 |
Output Power |
 |
50 W max
|
 |
Inhibit |
 |
Off = TTL Low or short circuit,
On = TTL High or open circuit |
| |
General |
 |
Efficiency |
 |
97% typical
|
 |
Resistance |
 |
0.25 Ω Input to Output,
<0.1 Ω Case to Case pin at 10 A |
 |
Power Dissapation Inhibited |
 |
0.1 W
|
 |
Inrush Current |
 |
25 A at 28 Vin
|
 |
Fusing |
 |
External fusing required
|
| |
MTBF |
|
846 kHrs to MIL-HDBK-217F GF at +40 °C |
| |
Environmental |
 |
Operating Temperature |
 |
-40 ºC to +85 ºC ambient,
-40 °C to +100 °C case.
Extended temperature range:
-55 ºC to +85 ºC ambient,
-55 °C to +100 °C case
|
 |
Storage Temperature |
 |
-50 ºC to +125 ºC
|
 |
Operating Altitude |
 |
Tested to 70000 Ft (21336 m)
|
| |
Operating Humidity |
|
88% relative humidity,
240h MIL-STD-810D method 507.2
|
 |
Shock |
 |
100 g MIL-STD-810D Method 516.3
|
 |
Vibration |
 |
10 to 2000 Hz
MIL-STD-810D Method 514.3 |
 |
Bump |
 |
2000 Bumps in each axes 40 g
MIL-STD-810D Method 516.3
|
 |
Salt Atmosphere |
 |
48 hours MIL-STD-810E Method 509.1 |
| |
EMC and Safety
|
 |
Conducted Emissions |
 |
EN55022 Conducted Level B, MIL-STD 461E:
CE101 & CE102
(These standards are met
when used in conjuction with the MTC Series)
|
 |
Immunity |
 |
MIL-STD-704E,
MIL-STD-704A & MIL-STD-1275A/B/C/D (These standards
are met when used in conjuction with the MTC Series)
|
 |
Conducted Susceptibility |
 |
MIL-STD-461E CS101, CS114, CS115, CS116
(These standards are met when used in
conjuction with the MTC Series) |
| |
|
|
|